Enterasys
®
SecureStack
C2
Gigabit Ethernet Switch
Hardware Installation Guide
C2K122-24
P/N 9034087-04
7.5x9-inch cover with bleed on 4 sides
Vista de pagina 0
1 2 3 4 5 6 ... 69 70

Indice de contenidos

Pagina 1 - SecureStack

Enterasys® SecureStack™ C2Gigabit Ethernet SwitchHardware Installation GuideC2K122-24P/N 9034087-047.5x9-inch cover with bleed on 4 sides

Pagina 2

viii 3. APPLICABLELAW. ThisAgreementshallbeinterpretedandgovernedunderthelawsandinthestateandfederalcourtsoftheCommonwealthofMas

Pagina 3 - Personal vorgenommen werden

ix8. AUDITRIGHTS. YouherebyacknowledgethattheintellectualpropertyrightsassociatedwiththeProgramareofcriticalvaluetoEnterasysand,ac

Pagina 5 - HAZARDOUS SUBSTANCES

xiContentsAbout This GuideWho Should Use This Guide ...

Pagina 6 - (Circuit Breakers)

xiiConfiguring Switches in a Stack ...3-10About Se

Pagina 7

xiiiFigures1-1 C2K122-24 Stackable Switch...1-23-1 XFP w

Pagina 9 - FIRMWARE LICENSE AGREEMENT

SecureStack C2 Installation Guide xvAbout This GuideThisguideprovidesanoverview,installati onand troubleshootinginstructions,andspecificatio

Pagina 10

Related Documentsxvi About This GuideThisprefaceprovidesanoverviewofthisguideandtheSecureStackC2manualset,abriefsummaryofeachchapte

Pagina 11

Conventions Used in This GuideSecureStack C2 Installation Guide xviiConventions Used in This Guide Thefollowingconventionsareusedinthisguide:No

Pagina 13 - Contents

Conventions Used in This Guidexviii About This Guide

Pagina 14 - Appendix A: Specifications

SecureStack C2 Installation Guide 1-11IntroductionThischapterintroducestheC2K122‐24stackableswitch.OverviewTheC2K122‐24isastackableswitch,

Pagina 15

Overview1-2 IntroductionC2K122-24TheC2K122‐24(Figure 1‐1)hasseveraltypesoffrontpanelportandrearpanel connections,whichinclude:•Twentyf

Pagina 16

ConnectivitySecureStack C2 Installation Guide 1-3High-Speed Stack ConnectionsTheswitchhasrear‐panelconnectorsforhigh‐speedconnectionsinastac

Pagina 17 - About This Guide

Management1-4 IntroductionManagementManagementofthemodulecanbeeitherin‐bandorout‐of‐band.In‐bandremotemanagementispossibleusingTelnet,

Pagina 18 - Related Documents

Getting HelpSecureStack C2 Installation Guide 1-5Getting HelpForadditionalsupportrelatedtotheswitchorthisdocument,contactEnterasysNetworks

Pagina 19

Getting Help1-6 Introduction

Pagina 20

SecureStack C2 Installation Guide 2-12Network RequirementsBeforeinstallingthedevice,reviewtherequirementsandspecificationsinthischaptercon

Pagina 21 - Introduction

100BASE-TX Network2-2 Network Requirements100BASE-TX NetworkWhenconnectinga100BASE‐TXsegmenttooneofthefixedports(1 through24),useCategor

Pagina 22 - C2K122-24

10GBASE-XX NetworkSecureStack C2 Installation Guide 2-3Theuplinkshaveonefiber‐opticinterfacewithanLCconnector.DependingontheXFPandfiber

Pagina 23 - Connectivity

iNoticeEnterasys Networksreservestherighttomakechangesinspecificationsandotherinformationcontainedinthisdocumentanditswebsitewitho

Pagina 24 - LANVIEW Diagnostic LEDs

10GBASE-XX Network2-4 Network Requirements

Pagina 25 - Getting Help

SecureStack C2 Installation Guide 3-13Hardware InstallationThischapterprovidesinstructionstoinstalltheC2 K122‐24.Followtheorderofthesecti

Pagina 26 - 1-6 Introduction

Considerations Prior to Installation3-2 Hardware InstallationConsiderations Prior to InstallationWheninstallingtheswitch,notethefollowing:•Befor

Pagina 27 - Network Requirements

Installing Optional XFPsSecureStack C2 Installation Guide 3-3Installing Optional XFPs ThissectiondescribeshowtoinstallXFPsinportslots25 and

Pagina 28 - areavailable.These

Installing Optional XFPs3-4 Hardware InstallationInstalling the XFPToinstallanXFPthathasanLCconnector,refertoFigure 3‐1,andproceedasfol

Pagina 29

Installing the Switch on a Flat SurfaceSecureStack C2 Installation Guide 3-5ToremoveanXFPfroma portslot,referbacktoFigure 3‐1,andproceeda

Pagina 30 - 2-4 Network Requirements

Installing the Switch on a Flat Surface3-6 Hardware InstallationFigure 3-2 Chassis Bottom, Rubber Feet Placement4. Removetheprotectivestripfromt

Pagina 31 - Hardware Installation

Rack Mounting the SwitchSecureStack C2 Installation Guide 3-7Thenextsteptoinstalltheswitchisdependentonthetypeofinstallation.Ifinstalli

Pagina 32 - Unpacking the Switch

Rack Mounting the Switch3-8 Hardware InstallationGuidelines for Rackmount InstallationTheinstallationsitemustbewithinreachofthenetworkcablin

Pagina 33 - Preparation

Connecting High-Speed Stacking CablesSecureStack C2 Installation Guide 3-9Figure 3-5 Fastening the Switch to the Rack3. Ifyouare installingthiss

Pagina 34 - Removing the XFP

ii REGULATORY COMPLIANCE INFORMATIONFEDERAL COMMUNICATIONS COMMISSION (FCC) NOTICEThisdevicecomplieswithPart15oftheFCCrules.Operationissub

Pagina 35 - Installing the Rubber Feet

Configuring Switches in a Stack3-10 Hardware InstallationFigure 3-6 High-Speed Stacking Cable ConnectionsAfterconnectingthecablestothestacking

Pagina 36 - Guidelines for Installation

Configuring Switches in a StackSecureStack C2 Installation Guide 3-11About SecureStack C2 Switch Operation in a StackTheSecureStackC2productsares

Pagina 37 - TX RX TX RX

Configuring Switches in a Stack3-12 Hardware InstallationRecommended Procedures for New and Existing StacksInstalling a New Stackable System of Up to

Pagina 38 - 3-8 Hardware Installation

Connecting AC and RPS PowerSecureStack C2 Installation Guide 3-131. Ensurethatpowerisoffonthe newswitchbeinginstalled.2. Useoneofthefoll

Pagina 39

Connecting AC and RPS Power3-14 Hardware InstallationFigure 3-7 Switch Rear View3. ObservethepowerCPULED(notshown)locatedonthefrontpanel.

Pagina 40 - 3 STACK UP connector

Connecting AC and RPS PowerSecureStack C2 Installation Guide 3-15RPS Power Ifyouareinstallinganoptionalredundantpowersystem(C2RPS‐SYS),refer

Pagina 41

Connecting to Console Port for Local Management3-16 Hardware InstallationConnecting to Console Port for Local ManagementThissectiondescribeshowto

Pagina 42 - Important

Connecting to Console Port for Local ManagementSecureStack C2 Installation Guide 3-17Connecting to an IBM or Compatible DeviceToconnectanIBMPCor

Pagina 43 - Connecting AC and RPS Power

Connecting to Console Port for Local Management3-18 Hardware InstallationConnecting to a VT Series TerminalToconnectaVTSeriesterminaltoanEnter

Pagina 44 - 3-14 Hardware Installation

Connecting to Console Port for Local ManagementSecureStack C2 Installation Guide 3-19Connecting to a ModemToconnectamodemtoanEnterasysNetworks

Pagina 45 - Stack Initialization Overview

iiiELECTROMAGNETIC COMPATIBILITY (EMC)Thisproductcomplieswiththefollowing:47CFRParts2and15,CSAC108.8,89/336/EEC,EN55022,EN61000‐3‐2,

Pagina 46 - What Is Needed

Connecting to the Network3-20 Hardware InstallationConnecting to the NetworkThefollowingprocedurescoverthecableconnectionsfromthenetworkoro

Pagina 47

Connecting to the NetworkSecureStack C2 Installation Guide 3-213. VerifythatalinkexistsbycheckingthattheLink /ActivityLEDisON(solidgreen

Pagina 48 - 3-18 Hardware Installation

Connecting to the Network3-22 Hardware InstallationFigure 3-14 Four-Wire Straight-Through Cable RJ45 Pinouts for 10/100BASE-TXFigure 3-15 Eight-Wire

Pagina 49 - Connecting to a Modem

Connecting to the NetworkSecureStack C2 Installation Guide 3-23Figure 3-16 Eight-Wire Straight-Through Cable RJ45 Pinouts for 10/100/1000BASE-TXConne

Pagina 50 - Connecting UTP Cables

Connecting to the Network3-24 Hardware InstallationEachfiber‐opticlinkconsistsoftwofiber‐opticstrandswithinthecable:•Transmit(TX)• Receive

Pagina 51

Connecting to the NetworkSecureStack C2 Installation Guide 3-25Figure 3-17 Cable Connection to LC Fiber-Optic Connectors3. Plugtheotherendofthe

Pagina 52 - 2 Other device port

Completing the Installation3-26 Hardware InstallationCompleting the InstallationAfterinstallingtheswitchandmakingtheconnectionstothenetwork,

Pagina 53

SecureStack C2 Installation Guide 4-14TroubleshootingThischapterprovidesinformationconcerningthefollowing:Thisdevicecontainsabatterythatis

Pagina 54 - 3-24 Hardware Installation

Using LANVIEW4-2 TroubleshootingUsing LANVIEWTheswitchsupportstheEnterasys N etworksbuilt‐inLANVIEWLEDvisualdiagnosticandstatusmonitoring

Pagina 55

Using LANVIEWSecureStack C2 Installation Guide 4-3Figure 4-2 LANVIEW LEDsLED Color State Recommended ActionCPU Off Power disconnected. If the LED rem

Pagina 56 - Completing the Installation

iv ѻѻક䇈ᯢк䰘ӊSupplement to Product Instructions ᳝↦᳝ᆇ⠽䋼៪ܗ㋴(Hazardous Substance) 䚼ӊৡ⿄(Parts) 䪙3E∲+J䬝&G݁Ӌ䫀&U໮⒈㘨㣃3%%໮⒈Ѡ㣃䝮3%&apo

Pagina 57 - Troubleshooting

Using LANVIEW4-4 TroubleshootingUP Off No valid connection to switch stackdown connector.1. Make sure the switch connected to the stackdown connector

Pagina 58 - 4-2 Troubleshooting

Troubleshooting ChecklistSecureStack C2 Installation Guide 4-5Troubleshooting ChecklistIfthedeviceisnotworkingproperly,refertoTable 4‐1fora

Pagina 59 - Figure 4-2 LANVIEW LEDs

Troubleshooting Checklist4-6 TroubleshootingCannot contact the switch through in-band management.IP address not assigned. Refer to the SecureStack C2

Pagina 60 - 4-4 Troubleshooting

Using the Password Reset SwitchSecureStack C2 Installation Guide 4-7Using the Password Reset SwitchIfyouforgettheswitchloginpassword,usethePa

Pagina 61 - Troubleshooting Checklist

Using the Password Reset Switch4-8 Troubleshooting

Pagina 62 - 4-6 Troubleshooting

SecureStack C2 Installation Guide A-1ASpecificationsThisappendixprovidesinformationaboutthefollowing:Enterasys Networksreservestherighttoch

Pagina 63 - STACK DOWN

Switch SpecificationsA-2 SpecificationsSwitch SpecificationsTable A‐1providestheI/Oports,processorsandmemory,physical,andenvironmentalspeci

Pagina 64 - 4-8 Troubleshooting

Supported XFP Transceiver Interface OptionsSecureStack C2 Installation Guide A-3Supported XFP Transceiver Interface OptionsAtthetimethismanualwas

Pagina 65 - Specifications

Console Port Pinout AssignmentsA-4 SpecificationsConsole Port Pinout AssignmentsTheConsoleportisaDB9serialcommunicationsportforlocalaccess

Pagina 66 - Switch Specifications

Index-1IndexNumerics1000BASE-Trequirements for 2-2100BASE-TXrequirements 2-210BASE-Tconnection 3-20requirements 2-110GBASE-XXrequirements for 2-2AAC i

Pagina 67

vVCCI NOTICEThisisaclassAproductbasedonthestandardoftheVoluntaryControlCouncilforInterferencebyInformationTechnologyEquipment(VCC

Pagina 68 - Regulatory Compliance

Index-2SSafety requirements A-4SpecificationsC2K122-24 A-2XFP A-3Stack initializationManager switch selection 3-15Stack Managerautomatic selection of

Pagina 69

vi DECLARATION OF CONFORMITYApplicationofCouncilDirective(s): 89/336/EEC73/23/EECManufacturer’sName: Enterasys Networks, Inc.Manufacturer’sAddres

Pagina 70

viiENTERASYS NETWORKS, INC.FIRMWARE LICENSE AGREEMENTBEFOREOPENINGORUTILIZINGTHEENCLOSEDPRODUCT,CAREFULLYREADTHISLICENSEAGREEMENT.Thisdocum