2H258-17R
SmartSwitch 2200
Installation User’s Guide
2H258-17R
COM
PWR
CPU
RESET
RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX
123456 8910 151611 12 14137
FAST ETHERNET WORKGROUP SWITCH
9033068-01
Vista de pagina 0
1 2 3 4 5 6 ... 61 62

Indice de contenidos

Pagina 1 - Installation User’s Guide

2H258-17R SmartSwitch 2200Installation User’s Guide2H258-17RCOMPWRCPURESETRX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX

Pagina 2

viii Contents3INSTALLATION3.1 Unpacking the Device ... 3-23.2 Instal

Pagina 3 - FCC NOTICE

Figures ixFigure PageFigures1-1 The 2H258-17R SmartSwitch 2200...1-13-1

Pagina 4 - BSMI EMC STATEMENT — TAIWAN

x Ta bl esTable PageTables3-1 Contents of 2H258-17R Carton ...3-24-1

Pagina 5 - PROGRAM LICENSE AGREEMENT

About This Guide xiAbout This GuideWelcome to the 2H258-17R SmartSwitch 2200 Installation User’s Guide. This guide describes the 2H258-17R SmartSwitch

Pagina 6

Related Documentsxii About This GuideChapter 4, Troubleshooting, describes the function of the LANVIEW LEDs, which can help to quickly diagnose networ

Pagina 7

Document ConventionsAbout This Guide xiiiThe HSIM-W6 Installation Guide, the HSIM-W84 Installation Guide, and the WAN Series Local Management User’s G

Pagina 9 - Contents

Introduction 1-11IntroductionThis chapter introduces the 2H258-17R SmartSwitch 2200 device and provides information about how to obtain additional sup

Pagina 10

Overview1-2 IntroductionThe 2H258-17R is used to connect individual high-bandwidth user devices, such as workstations, or to provide a central switchi

Pagina 11

OverviewIntroduction 1-3The RAD requests start at an interval of 1 per second. The interval then doubles after every transmission until an interval of

Pagina 13 - About This Guide

Overview1-4 Introduction1.1.6 Broadcast SuppressionBroadcast Suppression enables a user to set a desired limit of receive broadcast frames per port/pe

Pagina 14 - RELATED DOCUMENTS

OverviewIntroduction 1-51.1.9 Flow ControlFlow control is a method of managing the flow of frames between two devices. It ensures that a transmitting

Pagina 15 - DOCUMENT CONVENTIONS

Overview1-6 Introduction1.1.12 ManagementManagement of the 2H258-17R is accomplished using SNMP compliant management tools for in-band Local Managemen

Pagina 16

Getting HelpIntroduction 1-71.1.17 LANVIEW Diagnostic LEDsLANVIEW diagnostic LEDs serve as an important troubleshooting aid by providing an easy way t

Pagina 18 - 1.1.1 Connectivity

Network Requirements 2-12Network RequirementsBefore installing the 2H258-17R, review the requirements and specifications referred to in this chapter c

Pagina 20 - 1.1.8 Traffic Rate Limiting

Installation 3-13InstallationThis chapter provides the instructions required to install the 2H258-17R. A Phillips screwdriver is required to install o

Pagina 21 - 1.1.11 802.1 Port Priority

Unpacking the Device3-2 Installation3.1 UNPACKING THE DEVICEUnpack the device as follows:1. Open the box and remove the packing material protecting th

Pagina 22 - 1.1.16 Year 2000 Compliant

Installing the DeviceInstallation 3-33.3 INSTALLING THE DEVICEThe 2H258-17R may be installed on a tabletop, shelf, or in a 19-inch rack. Section 3.3.1

Pagina 23 - 1.2 GETTING HELP

NOTICEEnterasys Networks reserves the right to make changes in specifications and other information contained in this document and its web site withou

Pagina 24

Installing the Device3-4 InstallationFigure 3-1 Tabletop or Shelf Installation3.3.2 Rackmount InstallationTo install the 2H258-17R in a 19-inch rack,

Pagina 25 - Network Requirements

Installing the DeviceInstallation 3-5InstallationRack mounting the 2H258-17R involves the following:• Attaching the strain-relief bracket • Rack mount

Pagina 26

Installing the Device3-6 InstallationRack Mounting the 2H258-17RProceed as follows to install the 2H258-17R into a 19-inch rack:1. There are several m

Pagina 27 - Installation

Installing the DeviceInstallation 3-7Figure 3-4 Installing the Device in a Rack3.3.3 Connecting PowerTo connect the 2H258-17R to the power sources, pr

Pagina 28 - 3.2 INSTALLING OPTIONS

Connecting to the Network3-8 InstallationFigure 3-5 2H258-17R Rear View2. Observe the LANVIEW LEDs. After a successful boot, the PWR LED turns ON (gre

Pagina 29 - 3.3 INSTALLING THE DEVICE

Connecting to the NetworkInstallation 3-9Each fiber optic link consists of two fiber optic strands within the cable: the transmit (TX) and the receive

Pagina 30 - 3.3.2 Rackmount Installation

Connecting to the Network3-10 InstallationFigure 3-6 Fiber Optic Connection3. Plug the other end of the cable into the appropriate port on the other d

Pagina 31 - Bracket Screws

Completing the InstallationInstallation 3-113.5 COMPLETING THE INSTALLATIONAfter installing the 2H258-17R and any optional HSIM or VHSIM, and making t

Pagina 33 - 3.3.3 Connecting Power

Troubleshooting 4-14TroubleshootingThis chapter provides information concerning the following:• Using LANVIEW (Section 4.1)• Troubleshooting Checklist

Pagina 34 - 3.4 CONNECTING TO THE NETWORK

INDUSTRY CANADA NOTICEThis digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus set out in the Radio

Pagina 35

Using LANVIEW4-2 TroubleshootingTable 4-1 describes the LED indications and provides recommended actions as appropriate.Refer to the HSIM or VHSIM use

Pagina 36 - 3-10 Installation

Using LANVIEWTroubleshooting 4-3CPU Off Power off. Power up device.Red Blinking. Hardware failure has occurred.Contact Enterasys Networks for assistan

Pagina 37 - Installation 3-11

Troubleshooting Checklist4-4 Troubleshooting4.2 TROUBLESHOOTING CHECKLISTIf the 2H258-17R is not working properly, refer to Table 4-2 for a checklist

Pagina 38

Troubleshooting ChecklistTroubleshooting 4-5No Local Management Password screen.Autobaud is enabled, but the baud rate has not yet been detected.Press

Pagina 39 - Troubleshooting

Troubleshooting Checklist4-6 TroubleshootingCannot contact the 2H258-17R through in-band management.IP address not assigned. Refer to the SmartSwitch

Pagina 40

Troubleshooting ChecklistTroubleshooting 4-7User parameters (IP address, Device and Module name, etc.) were lost when the 2H258-17R power was cycled o

Pagina 41 - Troubleshooting 4-3

Using the RESET Button4-8 Troubleshooting4.3 USING THE RESET BUTTONThe RESET button shown in Figure 4-2 resets and re-initializes the 2H258-17R.Figure

Pagina 42 - 4.2 TROUBLESHOOTING CHECKLIST

Specifications A-1ASpecificationsThis appendix provides operating specifications for the Enterasys Networks 2H258-17R. Enterasys Networks reserves the

Pagina 43 - Troubleshooting 4-5

Electrical SpecificationsA-2 SpecificationsA.3 ELECTRICAL SPECIFICATIONSA.4 ENVIRONMENTAL REQUIREMENTSA.5 INPUT/OUTPUT PORTSLine Input Range, Volts (V

Pagina 44 - 4-6 Troubleshooting

COM Port Pinout AssignmentsSpecifications A-3A.6 COM PORT PINOUT ASSIGNMENTSThe COM port is a serial communications port that supports Local Managemen

Pagina 45 - Troubleshooting 4-7

ENTERASYS NETWORKS, INC.PROGRAM LICENSE AGREEMENTBEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT,CAREFULLY READ THIS LICENSE AGREEMENT.This document

Pagina 47 - Specifications

Optional Installations and Mode Switch Bank Settings B-1BOptional Installations andMode Switch Bank SettingsThe top cover must be removed to gain acce

Pagina 48 - A.5 INPUT/OUTPUT PORTS

Removing the Chassis CoverB-2 Optional Installations and Mode Switch Bank SettingsB.2 REMOVING THE CHASSIS COVERThis section describes how to remove t

Pagina 49 - A.7 REGULATORY COMPLIANCE

Removing the Chassis CoverOptional Installations and Mode Switch Bank Settings B-3To remove the chassis cover, proceed as follows: 1. Disconnect the 2

Pagina 50

Removing the Chassis CoverB-4 Optional Installations and Mode Switch Bank SettingsFigure B-1 Removing the Chassis Cover2504-30Note: If the device was

Pagina 51 - Mode Switch Bank Settings

Setting the Mode SwitchesOptional Installations and Mode Switch Bank Settings B-5B.3 SETTING THE MODE SWITCHESFigure B-2 shows the location of the mod

Pagina 52 - ÑOS, AL IGUAL QUE AL APARATO

Setting the Mode SwitchesB-6 Optional Installations and Mode Switch Bank Settings• Switch 6 – Forced BootP. DO NOT attempt a Forced BootP unless a Boo

Pagina 53

SIMM UpgradeOptional Installations and Mode Switch Bank Settings B-7B.4 SIMM UPGRADEMemory upgrade is available for the 2H258-17R to expand its DRAM t

Pagina 54 - Removing the Chassis Cover

SIMM UpgradeB-8 Optional Installations and Mode Switch Bank SettingsB.4.2 Installing the DRAM SIMMTo install a DRAM SIMM, refer to Figure B-4 and proc

Pagina 55 - B.3 SETTING THE MODE SWITCHES

Installing Optional HSIM or VHSIM Interface ModulesOptional Installations and Mode Switch Bank Settings B-9B.5 INSTALLING OPTIONAL HSIM OR VHSIM INTER

Pagina 56 - • Switch 6 – Forced BootP

3. APPLICABLE LAW. This Agreement shall be interpreted and governed under the laws and in the state and federal courts of New Hampshire without regard

Pagina 58 - SIMM Upgrade

Index-1IndexNumerics100BASE-Trequirements 2-12H258-17Rdescription of 1-1front panel 1-1802.1p Port Priorityintroduction to 1-5BBroadcast Suppressionin

Pagina 59 - Connectors

Index-2MManagementuse of 1-6Memoryupgrading B-7Mode Switchsetting B-5NNetwork connections 3-8PPhysical properties A-1Port redirect functionintroductio

Pagina 60

8. AUDIT RIGHTS. You hereby acknowledge that the intellectual property rights associated with the Program are of critical value to Enterasys and, acco

Pagina 61

DECLARATION OF CONFORMITYApplication of Council Directive(s): 89/336/EEC73/23/EECManufacturer’s Name: Enterasys Networks, Inc.Manufacturer’s Address:

Pagina 62

Contents viiContentsFigures ..............................