clear dhcp exclude
Enterasys D-Series CLI Reference 16-7
clear dhcp exclude
UsethiscommandtocleartheconfiguredIPaddressesthattheDHCPservershouldnotassignto
DHCPclients.
Syntax
clear dhcp exclude low-ipaddr [high-ipaddr]
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleclearsthepreviouslyexcludedrangeofIPaddressesbetween192.168.1.88through
192.168.1.100.
D2(rw)->clear dhcp exclude 192.168.1.88 192.168.1.100
set dhcp ping
UsethiscommandtoconfigurethenumberofpingpacketstheDHCPserversendstoanIP
addressbeforeassigningtheaddresstoarequestingclient.
Syntax
set dhcp ping packets number
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexamplesetsthenumberofpingpacketssentto3.
D2(rw)->set dhcp ping packets 3
lowipaddr SpecifiesthefirstIPaddressintheaddressrangetobecleared.
highipaddr (Optional)SpecifiesthelastIPaddressintheaddressrangetobecleared.
packetsnumber Specifiesthenumberofpingpacketstobesent.Thevalueofnumbercan
be0,orrangefrom2to10.Entering0disablesthisfunction.Thedefault
valueis2packets.