Overview of DFE-Diamond Module Shutdown Procedure
Matrix DFE-Platinum Series Module Installation Guide 4-7
Last Resort Shutdown Procedure Using OFFLINE/RESET Switch
ToresetaDFEDiamondmodulewithoutitperforminganorderlyshutdownroutine,
pressandholdthe OFFLINE/RESETswitchforapproximately6seconds.
PullinganyDFEDiamondmoduleoutofthechassisbeforeithasbeenshutdownisnot
recommended.Theonlysafetimetopullamoduleoutof
thechassisisafterthecompletionofa
shutdownandthemanagementLEDisflashingamber/off.
Caution: This method of shutting down a DFE-Diamond module is not recommended except as a
last resort, because all processes currently running on the module will be interrupted resulting in
loss of frames.
Precaución: No se recomienda utilizar este método para apagar los módulos DFE-Platinum.
Recurra a él sólo como último recurso, puesto que interrumpe todos los procesos del módulo en
funcionamiento, lo que podría resultar pérdidas de frames.