Enterasys-networks 1G58x-09 Manual de usuario Pagina 790

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 808
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 789
Security Configuration Command Set
Configuring Flow Setup Throttling (FST)
14-108 Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide
14.3.9.4 set flowlimit class
Use this command to assign a flow limiting user classification to one or more port(s). Once a
classification is assigned, these ports will be subject to the flow limit and action configured with the
set flowlimit limit command as described in Section 14.3.9.3.
set flowlimit port-string class {aggregationport | interswitchlink | serverport |
unspecified | userport}
Syntax Description
Command Type
Switch command.
Command Mode
Read-Write.
Command Defaults
None.
Example
This example shows how to assign the user port classification type to Fast Ethernet front panel ports
3-5:
port-string Specifies port(s) on which to assign user classification.
aggregationport |
interswitchlink |
serverport |
unspecified |
userport
Assigns a user classification type to the port(s) as:
aggregation port
interswitch link
server port
user port
unspecified port
Matrix>set flowlimit fe.0.3-5 class userport
Vista de pagina 789
1 2 ... 785 786 787 788 789 790 791 792 793 794 795 ... 807 808

Comentarios a estos manuales

Sin comentarios