EPIM-C (BNC PORT)
BRIM-E6 USER’S GUIDE Page 29
Power Meter, you must subtract 3 dBm from the measurement to correctly
compare those measured values to the values listed above (e.g., -29.5 dBm
peak = -32.5 dBm average).
A.4 EPIM-C (BNC PORT)
Internal Transceiver: Cabletron Systems TMS-3™ Transceiver
Connector Type: BNC receptacle, with gold center contact,
for use with BNC type tee-connectors and
RG-58 thin-net cable.
Figure A-4. EPIM-C (with BNC Port)
Termination: Using the switch to the side of the port, you can
internally terminate the port on the module via
a built-in 50 ohm terminator. This eliminates
the need to connect the port to a tee-connector
and terminator.
Grounding: For safety, connect only one end of a thin-net
segment to earth ground. Do not connect the
BNC port of an EPIM-C to earth ground.
Internal Termination Switch
= On (internally terminated)
= Off (need external termination)