clear summertime
D-Series CLI Reference 2-19
Defaults
Ifanoffsetisnotspecified,nonewillbeapplied.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowsetdaylightsavingstimetorecurstartingonthefirstSundayofAprilat
2a.m.andendingthelastSundayofOctoberat2a.m.withanoffsettimeofonehour:
D2(su)->set summertime recurring first Sunday April 02:00 last Sunday October
02:00 60
clear summertime
Usethiscommandtoclearthedaylightsavingstimeconfiguration.
Syntax
clear summertime
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoclearthedaylightsavingstimeconfiguration:
D2(su)->clear summertime
start_day Specifiesthedayoftheweektorestartdaylightsavingstime.
start_hr_min Specifiesthetimeofdaytorestartdaylightsavingstime.Formatis
hh:mm.
end_week Specifiestheweekofthemonthtoenddaylightsavingstime.
end_day Specifiesthedayoftheweektoenddaylightsavingstime.
end_hr_min Specifiesthetime
ofdaytoenddaylightsavingstime.Formatishh:mm.
offset_minutes (Optional)Specifiestheamountoftimeinminutestooffsetdaylight
savingstimefromthenondaylightsavingstimesystemsetting.Valid
valuesare1‐1440.