APPENDIX B: EPIM CABLE REQUIREMENTS
Page 36 BRIM-E6 USER’S GUIDE
B.1.5 AUI Cable Requirements
When you connect an external network segment to t an EPIM-A or EPIM-
X, the AUI cable must meet the following requirements:
AUI Cable
The AUI cable connecting the module to a device must be IEEE 802.3
type cable.
Length
The AUI Cable must not exceed 50 meters in length. If 28 AWG thin
office drop AUI cable is used, then the maximum cable length is limited to
50 feet (15.24 meters).
Grounding
The connector shell of the EPIM-A and the EPIM-X are connected to
ground.